With Labkotec oil and grease separator alarms, you’ll know the need to empty the separators in advance. Alarms help your business operate responsibly. Labkotec oil separator alarms are used, for example, at fuel distribution points, on roads and at airports. Our grease separator alarms are used in restaurants.
Keep the soil and groundwater clean
The Labkotec oil separator alarm monitors 24/7 and detects if the separator needs to be emptied to prevent oil from being wasted or risking an overflow into the soil or groundwater.
Grease separator alarms for restaurants
Labkotec grease separator alarms help your company operate responsibly by alerting you when grease separator needs to be emptied. When grease cannot clog drains, you avoid extra costs and odour nuisances. Ensure business continuity and a high level of hygiene in your restaurant operations.
Item no.: N/A idOil-20 Oil Separator Alarm
Learn More
idOil-20 alarm unit is used for oil separators and is designed for wall mounting. the idOil-20 alarm is easy to use.
It is possible to install up to three idOil sensors in the idOil-20 alarm unit. Following levels can be monitored:
The alarm unit will signal in such situations and the alarm information will be shown on the display.
Benefits:
Certification |
IP classification |
L x H x D |
Weight |
Supply voltage |
Ambient temperature |
Compatible sensors |
ATEX | IP65 | 175 x 125 x 75 mm | 750 g | 100-240V AC, 50/60 Hz | -30° C…+60° C | idOil-LIQ, idOil-OIL, idOil-SLU |
Item no.: N/A idOil-30 Battery (3G) Oil Separator Alarm
Learn More
idOil-30 is a battery-powered alarm unit for oil separators and is designed for wall mounting. idOil-30 is easy to use and is also available with a 3G modem.
It is possible to install up to three idOil-sensors in the idOil-20 alarm unit. Following levels can be monitored:
The alarm unit will signal in such situations and the alarm information will be shown on the display. The battery model is deactivated most of the time to save power and will become active during pre-set measuring intervals.
Benefits:
IP classification | Certification | L x H x D | Weight | Operating voltage | Ambient temperature | Compatible sensors |
IP65 | ATEX | 175 x 182 x 75 mm | 680 g (modem model 800 g) | 11-17 V DC | -30° C…+60° C | idOil-LIQ, idOil-OIL, idOil-SLU |
Item no.: N/A idOil-D30 Oil Separator Alarm
Learn More
idOil-D30 alarm unit is used for oil separators and is designed for mounting on a M36 DIN rail in an electrical cabinet. The idOil-D30 unit is easy to use and has a flexible, local configuration with WLAN as well as has alarm logging.
It is possible to install up to three idOil sensors in the idOil-20 alarm unit. Following levels can be monitored:
Benefits:
IP classification | Certification | L x H x D | Weight | Ambient temperature | Supply voltage | Compatible sensors |
IP20 | ATEX | 157 x 86 x 58 mm | 380 g | -30° C…+60° C | 100-240V AC, 50/60 Hz | idOil-LIQ, idOil-OIL, idOil-SLU |
Item no.: N/A idOil-Solar Oil Separator Alarm
Learn More
idOil-Solar Oil Separator Alarms are solar-powered alarms and communication units for monitoring levels of liquid hydrocarbon, sludge or high levels in oil and sand separators, where main power electricity is unavailable.
idOil-Solar Oil Separator Alarms can be equipped with beacon lights and/or 3G modems.
In case of alarm, idOil-Solar Oil Separator Alarm will either initiate a flashing beacon, send a text message (SMS) to pre-set phone numbers, or both. All alarms are visible locally in the idOil-Solar control unit, during the short wake-up period.
idOil-Solar Oil Separator Alarms remain deactivated most of the time, which mean that they consume minimum power. The device initiates at predetermined measurement intervals, in order to perform the sensor measurements. When equipped with a 3G modem, the device also starts listening at predetermined intervals, to receive any possible setting commands and simultaneously reports measurement values.
Comes with:
Benefits:
Types |
W x H x D |
Weight |
Operation temperature |
SP SolarSET signal light with high water level sensor | 200 x 400 x 132 mm | 8,0 kg | -30° C…+60° C |
SP SolarSET light with oil layer sensor | 200 x 400 x 132 mm | 8,0 kg | -30° C…+60° C |
SP SolarSET light with sludge layer sensor | 200 x 400 x 132 mm | 8,0 kg | -30° C…+60° C |
SP SolarSET light with high water level/oil layer sensor | 200 x 400 x 132 mm | 8,0 kg | -30° C…+60° C |
SP SolarSET light with oil layer/sludge layer sensor | 200 x 400 x 132 mm | 8,0 kg | -30° C…+60° C |
Item no.: N/A GA-series Grease Separator Alarm
Learn More
GA-series alarms are used to monitor the thickness of the grease phases that are accumulated in grease separators. The alarm will signal when the grease separator needs to be emptied and, thereby, hinders a harmful grease emission to the sewage system.
The GA-series grease separator alarms are available with one or two sensors:
Benefits:
Types | L x H x D | Weight | Supply voltage | Operation temperature | Sensor |
TT-GA-1 | 125 x 75 x 35 mm | 250 g | 230 V ±10%, 50/60 Hz | -30° C…+50° C | grease alarm sensor |
TT-GA-2 | – | 250 g | 230/115 V AC ±10%, 50/60 Hz | -30° C…+50° C | grease alarm sensor and blockage sensor |
Item no.: N/A Septic tank alarms – Lokaset 20
Learn More
Lokaset 20 septic tank alarm is a full alarm system for supervision of overflows in precipitation and collection tanks.
Lokaset 20 is a conductively controlled safety device consisting of a sensor unit and a control box. When the sensor comes in contact with a conductive fluid, the control box will put out a signal: turning on the red indicator lamp, buzzing starts, and disconnecting the alarm relay. By pressing the alarm receipt button, the buzzing will be turned off. The indicator lamp will continue to light up, and the relay will still be disconnected until the alarm is removed i.e., the sensor is no longer in contact with the fluid. The alarm is equipped with a 4-5 seconds delay to avoid unnecessary alarm because of splashes.
SET/LV sensor: The sensor and belonging cable are equipped with a fault-finding device that can localise breakdowns in the sensor circuit. The device is powered by 230VAC mains through a connecting cable with a standard plug. When the device is in on-mode, the alarm relay is in alarm setting i.e., disconnected. When the device is powered, a green light will turn on.
NOTE! The alarm must not be used for installations in areas with risk of environmental damages. SET/LV or SET/L sensor must not be installed in areas with risk of environmental damages.
It is not recommended to install SET/LV or SET/L sensor in areas where fumes, gasses, or fluids with possible corroding effects on the sensor are present e.g., aromatic and chlorinated hydrocarbons (PVC), strong bases or acids.
Comes with:
Benefits:
Types | Certification | W x H x D | Supply voltage | Ambient temperature | Compatible sensors |
SP Lokaset 20 | ATEX | 130 x 80 x 35 mm | 230 V ±10%, 50/60 Hz, 2,8 VA | 0° C…+50° C | SET/LV, SET/L |
Item no.: N/A TT-OMS-1 Oil Separator Alarm
Learn More
TT-OMS-1 Oil Separator Alarms are used to monitor oil phases that are accumulated in oil- and petrol separators. The system consists of a TT-OMS-1 control device, an OMS sensor and a cable joint.
TT-OMS-1 Oil Separator Alarms are designed specially for oil separators. The alarm indicates when it is time to empty the oil separator and thus prevents harmful hydrocarbon emissions to sewer systems.
TT-OMS-1 alarms are approved in accordance with ATEX Directive 2014/34/EU and IECEx.
TT-OMS-1 alarms are designed to comply to EN 858-1 & 2- and PPG3 norms. The alarms are especially suitable for smaller separators.
Benefits:
Types | Certification | L x H x D | Supply voltage | Ambient temperature | Compatible sensors |
TT-OMS-1 | ATEX | 175 x 75 x 35 mm | 230 VAC ±10%, 50/60 Hz | -30° C…+50° C | OMS sensor |
Item no.: N/A High water level alarms
Learn More
High Water Level Alarms can be installed in e.g., rainwater tanks, collection tanks, pumping wells, precipitation tanks, etc.
The alarm will signal at the pre-set height.
The level float is on top of the water and when it reaches the level switch, the alarm will signal.
Comes with:
Installation
Lower the level float down until reaching the wanted alarm level. Mount on the inside of the access shaft. The level float can be mounted on the service step for easy hoisting/lowering in case of service or adjustments.
Types | Width | Height | Depth |
SP-HA2 | 145 mm | 170 mm | 120 mm |